Multi-Angle Spectrophotometer Calibrations
On-site or laboratory calibration, with a personalized and flexible service. Delivery time: 5 days.
What do we calibrate?
Calibration of multi-angle spectrophotometers
Eyco performs calibration of measurement accuracy at 45º:
- The color coordinates for 6 points: 3 grays with different luminance and 3 colors.
- The color differences for 2 pairs: 1 pair of gray and one pair of green.
Calibration of the measurement accuracy for the aspecular angles of 15º, 25º, 45º, 75º and 110º, for a white standard.
Determination of the repeatability of the equipment on a white pattern, for the 45º angle.
Calibration for a measurement condition: 1 observer and 1 illuminant.
Multi-angle spectrophotometers
A multi-angle spectrophotometer, or gonio-spectrophotometer, allows for obtaining colorimetric information for the same illumination angle but different viewing angles. These instruments are especially valuable in industrial sectors that work with metallic finishes, pearlescent effects, or iridescent coatings—that is, materials whose visual appearance changes depending on the viewing angle due to optical phenomena.
Specifically, sectors such as automotive The cosmetics and colorimetry industries frequently use this measurement technology. Thus, in these sectors, where colorimetry plays a critical role, having an objective method for evaluating colorimetry becomes indispensable. Furthermore, this becomes even more relevant when products and materials have complex characteristics that require measurement from different viewing angles.
Multi-angle spectrophotometers evaluate color based on geometry (illumination and observation angle), illuminant (type of light) and observer.
Geometry
Multi-angle spectrophotometers illuminate the sample or product to be measured at an angle of 45º and evaluate the light reflected at specular angles of 15º, 25º, 45º, 75º and 110º.

Illuminant
It is the type of light that falls on the sample whose color is to be measured. Thus, it is a spectral distribution curve of the light sources.
Specifically, colorimeters and spectrophotometers commonly use illuminants D65, D50, A, and C. Illuminants D65 and D50 correspond to daylight, while illuminant A refers to artificial light and simulates incandescent light.
In addition, there are also illuminants that reproduce fluorescent light sources, although their application is limited to specific cases or to those requirements established by particular testing standards.
Observer
Finally, color detection and quantification require an observer. The CIE has established several standardized observers, each representing a specific field of view. Specifically, the defined standard observers are the 2° and 10° observers, the latter being the most widely used. However, the choice between one or the other is determined by the specific needs of each company and the requirements of the industry in question.
Technical scope for calibration of multi-angle spectrophotometers
Eyco has accreditation ENAC to calibrate in the illuminant and observer conditions that the company demands. Eyco performs the calibration in CIELab* or Yxy chromatic coordinates, and in DE* color differences.
| Measurement range Range | Uncertainty (*) -- | Standard/Procedure -- | Instruments to be calibrated Instruments | Dress Code |
|---|---|---|---|---|
| Color, coordinates (L*,a*,b*),(Y,x,y) color difference dE*(geometry 0°:45a) Color, coordinates (L*,a*,b*),(Y,x,y) color difference dE* (0°:45a geometry) | ||||
| 80 ≤ L*≤ 100 – 1 ≤ a*≤ 1 – 1 ≤ b*≤ 1 80 ≤ Y ≤ 100 0,30 ≤ x ≤ 0,35 0,30 ≤ y ≤ 0,35 | 0,20 0,70 0,30 0,50 0,0020 0,0020 | PT40 Procedure internal based on: IUPAC Recommended Reference Materials for realization of Physicochemical properties CIE 15 | Multi-angle spectrophotometers Angles of 15°, 25°, 45°, 75° and 110°. | A,I |
The result
Once your equipment has been calibrated by Eyco's expert staff, you will receive a Calibration Certificate backed by accreditation. ENAC. Said Certificate includes the complete identification of your equipment, the procedure that the laboratory has followed to carry out the calibration and the result of the same.
The result of calibrating multi-angle spectrophotometers is a correction along with its uncertainty. This correction is the difference between the value of the reference standard and the value measured by your instrument. The Calibration Certificate issued by Eyco will provide the chromaticity coordinate correction for six standards and the color difference correction for 45°:0° geometries.
For each of the specular angles, you will receive the Lab* color coordinate correction for a pattern, along with its expanded uncertainty.
From the correction values and their uncertainty, you can establish the acceptance and rejection values of the equipment.
In addition, together with your equipment, you will receive a calibration label with the certificate number, the identification of the equipment and the date of calibration.