Transmission Color Standard Calibrations
Personalized and flexible service. Delivery time: 5 days.
What do we calibrate?
Calibration of transmission color patterns.
ENAC accredited calibration service.
Calibration in tristimulus XYZ values and CIELab*/Yxy coordinates.
Calibration service for one measurement condition: 1 geometry (0º:0º; 0º:di), 1 illuminant (A, C, D50 or D65) and 1 observer (2º or 10º)
Transmission Color Standards
Color standards are often used to verify equipment daily, to compare different pieces of equipment within the same company, to perform periodic checks, or to calibrate equipment internally.
Specifically, transmission color patterns are calibrated for the necessary conditions of geometry, illuminant, and observer.

Transmission Color Standards
Reference standards are usually supplied with transmission spectrophotometers and colorimetersThese standards require maintenance and are characterized by their stability. Colorimetric transmission standards are used to routinely adjust the equipment to verify accurate color transmission measurements.
For proper maintenance of the standards, it is recommended to avoid the presence of dust, fingerprints, damage, scratches, etc. Specifically, periodic checks will allow verification of whether their chromaticity coordinates are altered. The calibration of the standards is performed under the same geometry, illuminant, and observer conditions as those used by the equipment.
When color standards are used for equipment intercomparison within the same company, standards must be available that have been maintained in good condition and have been calibrated, where the values of the chromatic coordinates are known and stable, so that the same standard can be measured by different equipment.
In addition, colorimetric transmission standards can also be used for regular checks. Checks can also be performed during the time that elapses between each external calibration. The calibration of standards guarantees the certainty of the chromatic coordinates of the same.
Color measurement conditions
To measure the color It is necessary to know the measurement conditions: the geometry, the illuminant, and the observer.
Eyco is the only laboratory in Spain accredited for the calibration of equipment and standards for the measurement of chromatic coordinates and tristimulus values in transmission.
Geometry
Geometry 0º:0º and 0º:di. Transmission color can be measured in 0º:0º and 0º:di geometries. These geometries are used in colorimeters and transmission standards, to measure liquids and translucent solids (glass, plastic, etc.)
Observer
The types of observers have been standardized by the CIE (2nd and 10th). Each observer represents a different visual field. The measurements with one or the other observer depend on the type of sector and industrial activity, although the most common is that companies carry out the measurements under the condition of 10º observer.
Illuminant
Finally, the illuminant is the spectral distribution curve of the light sources, that is, the type of light that falls on the sample to be measured.
Specifically, the most commonly used are D65, D50, A, and C. Illuminants D65 and D50 correspond to daylight, while illuminant A simulates incandescent artificial light. There are also illuminants that simulate fluorescent light sources.

Technical scope for calibration of transmission color standards
| Measurement range Range | Uncertainty (*) -- | Standard/Procedure -- | Instruments to be calibrated Instruments | Dress Code |
|---|---|---|---|---|
| Color, coordinates L*a*b*Y xy; Tristimulus values X,Y, Z (0º:0º and 0º:di) Color, coordinates L*a*b*Y xy; Tristimulus values X,Y, Z (0º:0º and 0º:di) | ||||
| 0≤ L≤ 100 -150 ≤ a ≤ 150 -150 ≤ b* ≤ 150 0≤X≤100 0 ≤ Y ≤ 100 0≤ Z≤ 100 0,1000 ≤ x ≤ 0,9000 0,1000 ≤ y ≤ 0,9000 | 0,10 0,40 0,40 0,10 0,10 0,10 0,0010 0,0010 | PT51 Internal procedure based on: CIE 15 | Colorimetric transmission patterns/filters | A |
The result
Once your equipment has been calibrated by Eyco's expert staff, you will receive a Calibration Certificate backed by accreditation. ENAC.
Said certificate includes the complete identification of your equipment, the procedure that the laboratory has followed to carry out the calibration and the result of the same.
The result of the calibration is the value of the color units of each pattern for each geometry together with its expanded uncertainty.
Based on the correction values and their uncertainty, you can establish the acceptance and rejection values for the equipment.
In addition, together with your equipment, you will receive a calibration label with the certificate number, the identification of the equipment and the date of calibration.